CMP201D User Guide
Click Advance Parameters to set Encoding Parameters & Stream Output Parameters &
MPEG-2 Output Parameters & MPEG4/MPEG4_AVC Output Parameters & Other Parameters
for CH1.1/CH2.1 separately.
CE2-SDI-00>Output
This feature is specifically for single program encoding and IP output directly. Outputting in this way
will not occupied baseboard multicast bandwidth.
If you want to use IP output channel in the encoder module and baseboard TSoIP module at
same time, you should avoid a multicast IP address conflict. If there are two same IP addresses
enabled meantime, all the multicast videos will be affected.
Destination IP Address and Destination Port: Using for multicast IP addresses or unicast IP
addresses and ports.
Enable Destination MAC: Generally, you do not need to enable this option. This is reserved for
exceptional case when the unicast stream cannot be received by using unicast IP addresses,
you can enable destination MAC and streaming out by setting Destination MAC.
To use Multiplexing mode at service level:
1. Click on the pencil icon . There will always be a BaseBoard selection for the IP output and
other Output options depending on the module inserted.
2. Select the correct Output and Channel you want to output the service to.
3. Check Multiplex on the channel you want to output to. You can output multiple services to one
channel or output one service to multiple channels.
The second eth is reserved to output IP streams in an another different VLAN. Enabling the second
eth and set IP Address, Subnet Mask, Default Gateway in the same segment of the Unicast IP (the
another different VLAN), you can output the Unicast stream to the another VLAN.
CE2-SDI-00 >EAS Settings
This function need to be used together with CP2-EAS-00 module.