EasyManuals Logo

Wilo RP Series User Manual

Wilo RP Series
Go to English
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
23
ENGLISH
Check capacitor size in the case
of 1-phase pumps (observe name
plate data!)
Rotor shaft has jammed e.g. by
incrustations from the heating
water.
Remedy: Remove central vent
plug, check free movement of
shaft or free respectively at the
slotted shaft end by means of a
screwdriver.
At high water tempera-
tures and system pres-
sures, close isolating val-
ves at both pump ports.
First, allow pump to cool
down.
On overload release check relay
setting.
8.2 Noise
Cavitation due to insufficient inlet
pressure
Remedial actions:
Increase system pressure within
permissible limits.
Check speed setting, if need
be, adjust to a lower speed set-
ting
If the fault cannot be located or
rectified, please contact your
nearest WILO representative.
9 Spare parts
Available spare parts:
Pump housing, complete,
Exchange pump head, complete,
Terminal box, complete,
Housing gasket,
Flap valve, complete (DOP/DOS
only)
State all name plate data when or-
dering spare parts.
Technical modifications reserved.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo RP Series and is the answer not in the manual?

Wilo RP Series Specifications

General IconGeneral
BrandWilo
ModelRP Series
CategoryWater Pump
LanguageEnglish

Related product manuals