EasyManuals Logo

WinGD X62DF-S2.0 User Manual

Default Icon
259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Marine Installation Manual 2022-03 2-7
2 Engine Power and Speed
2.5 Power range limits
X62DF-S2.0
Line 5
Engine Operation
Power Limit
Admissible power limit for engine operation. The line is separated by the break-
points listed in Figure 2-3,  2-6.
Line 6
Transient Operation
Power Limit
Maximum power limit for transient operation, available only in diesel mode.
The line is separated by the breakpoints listed in Figure 2-3,  2-6.
Line 7
Nominal Engine
Characteristic
Nominal engine characteristic curve that passes through the CMCR point is de-
fined by the propeller law:
Formula 2-3
Line 8
Light Running
Propeller Curve
Propeller curve with a light running margin (typically between 4% and 7 %).
The curve is defined by the propeller law with a constant, governed by the se-
lected light running margin (Formula 2-4).
Formula 2-4
where:
P
LR
........... = propeller power at selected light running margin [kW]
P
CMCR
....... = CMCR engine power [kW]
n ............... = selected engine speed [rpm]
n
CMCR
....... = CMCR engine speed [rpm]
C .............. = constant
LR ............ = light running margin [%]
Line 9
CMCR Power
Maximum power for continuous operation.
Line 13
110% CMCR Power
Constant power overload limit, available for testbed operation and emergency
operation according to SOLAS Regulation II-1/3.6.
3
CMCR CMCR
Pn
Pn
æö
÷
ç
÷
ç
=
÷
ç
÷
÷
ç
èø
3
LR
CMCR CMCR
P
n
C
Pn
æö
÷
ç
÷
ç
=â‹…
÷
ç
÷
÷
ç
èø
3
1
1
C
L
R
=
+
æö
÷
ç
÷
ç
÷
ç
÷
ç
èø

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WinGD X62DF-S2.0 and is the answer not in the manual?

WinGD X62DF-S2.0 Specifications

General IconGeneral
BrandWinGD
ModelX62DF-S2.0
CategoryMarine Equipment
LanguageEnglish