31
27 Technical data
General
Minimum flow pressure
150 kPa (1.5 bar)
Maximum inlet pressure (back
pressure)
600 kPa (6.0 bar)
Inlet water temperature
10 60 °C
Voltage
see rating plate
Total connected load
Fuse protection
Operating conditions
Operating temperature
0 - 40 °C
Relative humidity
< 95%
Storage temperature
> -10 °C
Maximum height of the installation
location above sea level
3000 m
28 Emissions
Noise
Workplace-related emission sound pressure level L
pA
< 70 dB
Measurement uncertainty: K(pA): 4 dB
Exhaust air
Adhere to the VDI Guideline 2052 when designing the ventilation system.
Recommended extraction volume per exhaust air vent* (depending on the environmental
conditions): 350 - 700 m
3
/h
*) Optional