EasyManua.ls Logo

Wintriss SmartPAC PRO - Table 2-6. Dipro Sensor Interface (DSI) 2 to Smartpac PRO Wiring, Sensors 17-24

Wintriss SmartPAC PRO
318 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SmartPAC PRO User Manual 1143100
Chapter 2 – Installing SmartPAC PRO 65
Table 2-6. DiPro Sensor Interface (DSI) 2 to SmartPAC PRO Wiring, Sensors 17-24
Wire color*
3rd DSI 2 (TB2)
DiProPAC (TB555)
Pin #
Pin Designation
Pin #
Pin Designation
Brown
1
SENSOR 1
180
SENSOR 17
Red
2
SENSOR 2
181
SENSOR 18
Orange
3
SENSOR 3
182
SENSOR 19
Yellow
4
SENSOR 4
183
SENSOR 20
Green
5
SENSOR 5
184
SENSOR 21
Blue
6
SENSOR 6
185
SENSOR 22
Violet
7
SENSOR 7
186
SENSOR 23
Gray
8
SENSOR 8
187
SENSOR 24
No connection
188
Sensor power
Black
9
GND
189
GND
10
GND
No connection
11
+5 VDC
No connection
Shield
Terminate drain wire to ground
stud
Terminate drain wire to ground
stud
* Your colors may be different

Table of Contents