Chapter 2 – Installing SmartPAC PRO 83
Chapter 8 for counter preset messages).
• If the press top-stopped correctly, go to step 7.
• If the press did not top-stop and SmartPAC PRO displayed a message, there is a wiring
problem in your top-stop circuit. Recheck all wiring and trace the cause of the problem.
Check the Emergency-stop Circuit
7. Perform the 90stop-time test to verify that the emergency-stop circuit is working, referring to
the procedure starting on page 150.
• If the press stops correctly, go to step 8.
• If the press does not stop, there is a wiring problem in your emergency-stop circuit. Recheck
all wiring and trace the cause of the problem.
Check Cam Channels (ProCamPAC Only)
8. Create some test settings for your cam channels in Program mode (see Run Mode: CAM SWITCH
(ProCamPAC), page 218), load the tool settings, and switch to Run mode to run the press. Ensure
that the equipment (feed, blow off, lube, etc.) controlled by each channel is operating
appropriately according to the settings you made.
Test Complete
9. If you get to this step, SmartPAC PRO is working correctly. Clear any error messages by pressing
RESET, then delete the test tool. You can now create a tool in SmartPAC PRO, program settings
for it, load it, and begin to make parts using your new SmartPAC PRO.
What Next?
To program and use your SmartPAC PRO, follow the instructions in the remaining chapters of this
manual. Go to Chapter 3 to make Initialization settings for your SmartPAC PRO.