Rotary joint threaded connection
Fig: Threaded connection of rotary joint
Fillingthetrap
Prior to opening the gas ball valve and acknowledging
the fault:
• Remove the trap.
• Fill the trap with water up to the mark.
• Retthetrap.
• Open the gas ball valve and acknowledge the fault.
• Switch ON the condensing boiler at the red ON/OFF
switch in the WOLF logo.
Note:
The condensate hose attached to the trap must not form
a loop or roll up, as this could lead to impaired operation.
Trap
Fig: Trap
25.Fillingtheheatingsystem/trap
When installing an automatic vent, lock the
lower threaded connection of the rotary joint
underneaththecombustionchamberoor.
• Check the system pressure again and top up with
water if required.
Note:
During continuous operation, the heating circuit is auto-
maticallyventedviathehighefciencypump.
Please
note