4. Control/Function/Operation
Note:
The number of times the condensing boiler can be started in heating mode is limited
electronically. This limit can be bypassed by pressing the reset button. Then, the boiler
starts immediately, as soon as there is a heating demand.
In summer mode, the circulation pump operates for approx. 30 seconds after a maxi-
mum idle period of 24 hours.
Anti-seizingpumpprotection
Setting
Wintermode (positions 2 to 8)
In winter mode, the boiler heats to the temperature selected at the heating water temper-
ature controller. According to the pump operating mode, the circulation pump operates
constantly (factory setting) or only in parallel with the burner activation / run-on period.
Summermode
Winter mode is disabled by rotating the heating water temperature selector into posi-
tion . In other words, the boiler will then operate in summer mode. Summer mode
(heatingOFF)meansonlyDHWheating.Frostprotectionfortheheatingsystemand
pump anti-seizing protection, however, remain enabled.
Emissionstestmode
The emissions test mode is activated by rotating the heating water temperature selector
into position
.Theilluminatedsignalringashesyellow.Aftertheemissionstestmode
has been activated, the boiler will heat with the selected maximum heating output. Any
previous cycle block will be cancelled. The emissions test mode terminates after 15
minutesorwhenthemaximumowtemperaturehasbeenexceeded.Toreactivate,turn
the heating water temperature selector anti-clockwise and then back into position
.