3. Standardsandregulations
GascondensingboilerCGB-...
Gas condensing boiler to DIN EN 437 / DIN EN 13203-1 /
DIN EN 15502-1 / DIN EN 15502-2-1 / DIN EN 60335-1 /
DIN EN 60335-2-102 / DIN EN 62233 / DIN EN 61000-3-2 /
DIN EN 61000-3-3 / DIN EN 55014-1, as well as 92/42/
EWG (Efciency Directive) / 2016/426/EU (GasApplianc-
es Directive) / 2014/30/EU (EMC Directive) / 2014/35/
EU (Low Voltage Directive) / 2009/125/EG (ErP Directive) /
2011/65/EU (RoHS-Richtlinie) /Regulation (EU) 811/2013 /
Regulation (EU) 813/2013, with electronic ignition and elec-
tronicue gastemperature monitoring,for lowtemperature
heatingandDHWheatinginheatingsystemswithowtemper-
atures up to 90°C and 3 bar permissible operating pressure in
accordance with DIN EN 12828. This WOLF gas condensing
boiler is also approved for installation in garages.
Open ue gas condensing boilers must only
beinstalledinaroomwhichcomplieswiththe
appropriateventilationrequirements.Otherwise
there is a risk of asphyxiation or poisoning.
Readtheinstallationandmaintenanceinstruc-
tionsbeforeinstallingtheboiler.Alsotakeinto
considerationalltechnicalinformation.
WhenoperatingtheboilerwithLPG useonly
propaneaccording to DIN 51 622,otherwise
faults may arise when starting and operating
thegascondensingboiler,whichmayleadto
damagetotheapplianceandpersonalinjury.
ApoorlyventedLPGtankcanleadtoproblems
withignition.Insuchacase,contactthecom-
panythatllstheLPGtank.
Theadjustablecylinderwatertemperaturecan
exceed60°C.Forshorttermoperation above
60°Ctheboilermustbemonitoredinorderto
prevent scalding. For continuous operation,
appropriate precautions should be taken to
preventdraw-offtemperaturesabove60°C,e.g.
thermostaticvalves.
Fig.: Wolf gas condensing boiler
Toprotectagainstscaling,theDHWtemperatureshould
besettomax.50°Cifthetotalwaterhardnessis15°dH
(2.5 mol/m³) or above. Without an accessoryregulator,
thiscorrespondstoamaximumhotwaterrotaryselector
settingof6.Withatotalhardnessof20°dHorhigher,use
ofawatertreatmentfacilityinthecoldwatersupplyline
whenheatingDHWisnecessaryinordertoextendthe
maintenanceintervals.
Failuretotakesuchprecautionswillresultinpremature
scalingoftheapplianceandareductionintheconvenient
availabilityofdomestichotwater.Thecontractorrespon-
sibleshouldalwayscheckthelocalconditions.