Troubleshooting
3–6 975-0188-01-01
Hot
Green 100% indicator light
flashes
Green bank indicator light for
the affected battery bank
illuminated
Battery too
Hot Warning
Allow battery to cool. Improve ventilation
or install in cooler location. It may
indicate a shorted cell in the battery or
excessive water loss. If the temperature
increases, the BC Series will enter the
fault level and stop charging the affected
bank.
Err
Hot
Red fault indicator light
illuminated
Green 100% indicator light
flashes
Green bank indicator light for
affected battery bank
illuminated
Battery too
Hot Shutdown
Allow battery to cool. Improve ventilation
or install in cooler location. It may
indicate a shorted cell in the battery or
excessive water loss.
no
Cannot apply
change
The operation you have tried to execute
cannot be completed.
Err
no
Bat
Red fault indicator light
illuminated
No batteries
detected
The charger did not detect any batteries.
Table 3-2
Error Messages
Display
Onboard Status Panel
Indicator lights Fault Solution
BC_Charger_User.book Page 6 Friday, August 12, 2005 3:31 PM