Troubleshooting
To view a fault list:
1. On the Select Device menu, highlight System and press
Enter.
2. On the System Settings menu, highlight View Fault List.
3. Press Enter.
Manual fault Requires you to clear it by:
Selecting Clear Faults on the Freedom
SW or on the device that generated the
detected fault (if the condition still
exists, the fault message reappears).
Correcting the condition that detected
the fault.
Escalating
automatic
faults
Clears automatically if the detected fault
condition goes away, just like an automatic
fault.
However, if an escalating automatic fault
occurs several times within a defined time
period, the escalating automatic fault
becomes a manual fault, requiring user
intervention. For example, if three detected
faults occur in one minute, it will no longer
clear itself but becomes a manual fault.
Then, you must identify the problem,
correct the condition that detected the fault,
and clear the fault or reset the device.
Table 1 Detected Fault Types and Behaviors
Fault type Behavior
FSW Owners Guide.book Page 89 Tuesday, August 7, 2018 9:03 AM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom SW Series and is the answer not in the manual?

Xantrex Freedom SW Series Specifications

General IconGeneral
BrandXantrex
ModelFreedom SW Series
CategoryInverter
LanguageEnglish

Related product manuals