6. Place the unit into the mounting plate and secure it with four #6
screws.
7. Peel off the protective plastic coating covering the screen and
indicator light.
To flush mount the System Control Panel with no mounting plate:
1. Peel the backing from the supplied mounting template sticker and
place it in your chosen installation location. Use the template to mark
the location for the area to be cut out.
2. Pilot-drill the mounting holes (if necessary, depending on your
mounting surface) and, using a jigsaw, cut out the hole in which the
System Control Panel will be inserted.
3. Route the Xanbus cable(s) from other Xanbus-enabled devices inside
the wall and through the opening.
4. Connect the Xanbus cable(s) (and terminator if necessary) to either
network input on the back of the System Control Panel. See Figure 2-
9.
Connect a network terminator to the System Control Panel if it is the
last device at the end of a daisy chain network layout.
5. Place the unit in the opening and secure it with four #6 screws.
6. Peel off the protective plastic coating covering the screen and
indicator light.