not less than 300 rpm for three
consecutive times after the
completion of the pulse instruction,
the driver will alarm.
(4) Contact manufacturers for
technical support
5 E-265
Excessive motor
vibration
Mechanical vibration
(1) Set P2-03.0 to 0;
(2) Check motor installation
28
0 E-280
read motor code inside
encoder error
Request to read
EEPROM failed
(1) Check the disconnection of
encoder;
(2) On the premise that the
professional determines that the
driver and motor are matched and
can be used together, it can (read
the motor parameter alarm
shielding bit) through P0-53 and
correctly set P0-33 motor code
1 E-281
An error occurred
while writing data to
the encoder EEPROM
Request to write
EEPROM failed
On the premise that the professional
determines that the driver and motor
are matched and can be used
together, it can (read the motor
parameter alarm shielding bit)
through P0-53 and correctly set P0-
33 motor code
30 0 E-300 motor code error
Motion bus
communication
abnormal
Check the motion bus wiring
31
0 E-310 motor code lost Motor code is error
Set correct motor code and power
on again
1 E-311
The motor code does
not match the software
version
Not set motor code Set the motor code in P0-33
2 E-312 Reading motor There are motor On the premise that the professional
88