Appendix special soft device list
3 O mapping
ID
Function
Initial value
Description
FD8074
Y00 corresponds with I**
0
Y0 corresponds with the number of
output image O**
FD8075
Y01 corresponds with I**
1
Initial value are all decimal
FD8076
Y02 corresponds with I**
2
……
……
FD8137
Y77 corresponds with I**
63
4 I property
ID
function
Initial value
Description
FD8138
X00 property
all be 0
0: positive logic;
others: negative logic
FD8139
X01 property
FD8140
X02 property
……
……
FD8201
X77 property
5 power-off retentive area of soft components
Soft
component
FD
REGISTER
FUNCTION
Default
value
Power-off retentive
range
XC1
series
D
FD8202
Start tag of D power off
retentive area
100
D100~D149
M
FD8203
Start tag of M power off
retentive area
200
M200~M319
T
FD8204
Start tag of T power off
retentive area
640
-
C
FD8205
Start tag of C power off
retentive area
320
C320~C631
S
FD8206
Start tag of S power off
retentive area
512
-
XC2
series
D
FD8202
Start tag of D power off
retentive area
4000
D4000~D4999
M
FD8203
Start tag of M power off
retentive area
3000
M3000~M7999
T
FD8204
Start tag of T power off
retentive area
640
-
C
FD8205
Start tag of C power off
retentive area
320
C320~C639
S
FD8206
Start tag of S power off
retentive area
512
S512~S1023

Table of Contents

Other manuals for Xinje XC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XC Series and is the answer not in the manual?

Xinje XC Series Specifications

General IconGeneral
BrandXinje
ModelXC Series
CategoryController
LanguageEnglish

Related product manuals