5 Input Specifications and Wiring Methods
XCC series
32
5
0
5
2Input Terminals of HSC:
Each letter’s description:
U
Dir
A
B
Counter's pulse input
Counter's direction judgment
(OFF: increment counter, ON: decrement counter)
A phase input
B phase input
Normally, X0, X1 terminals’ input frequency can reach 80KHz under single-phase and AB phase
mode; the other terminal’s input frequency can reach 10KHz under single-phase mode and 5KHz
under AB phase mode. If X input terminals are not used as high speed input port, they can be used
as common input terminals. The detailed port assignment is shown below:
Note:
1. XC2-16: C600, C602, C620, C630 max frequency is 10KHz;
2. XC2-14: max frequency is 10 KHz.
XC2 series PLC
Increment Mode
Pulse + direction mode
AB phase mode
C600
C602
C604
C606
C608
C610
C612
C614
C616
C618
C620
C622
C624
C626
C628
C630
C632
C634
Highest
frequency
80K
80K
10K
10K
10K
80K
10K
80K
5K
4 times
frequency
Counter
interruption
X000
U
U
A
X001
U
Dir
B
X002
X003
U
U
A
X004
Dir
B
X005
X006
U
X007
U
X010
X011
X012

Table of Contents

Other manuals for Xinje XC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XC Series and is the answer not in the manual?

Xinje XC Series Specifications

General IconGeneral
BrandXinje
ModelXC Series
CategoryController
LanguageEnglish

Related product manuals