EasyManua.ls Logo

XTA 5 series - Input Section

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Series 5 Series
5 Series Operator’s Manual Page 3
5 Series
5 Series5 Series
5 Series Quick Reference
Editing channels : press channel’s GAIN key. First press accesses
that channel’s gain. To scroll through channel’s parameters, use the
BACK and NEXT keys. Second press accesses last viewed parameter.
Third press will drop back to the default screen.
Accessing menus: press the MENU key. Use the BACK and NEXT
keys to select the sub-menu required, and enter the sub-menu using the
ENTER key. This applies to all levels of menu. ENTER always
confirms selections.
The Menus and their Contents
GLOBAL MEMORY
GLOBAL MEMORY GLOBAL MEMORY
GLOBAL MEMORY Sub-menu: Recall/Store/Erase input, graphic
EQ, dynamic EQ, and crossover settings, or combinations of these.
INPUT SECTION
INPUT SECTIONINPUT SECTION
INPUT SECTION Sub-menu: Set up input ganging, and GEQ ‘Q’
setting.
CROSSOVER
CROSSOVERCROSSOVER
CROSSOVER Sub-menu: Set up or adjust crossover design, including
routing and auto limiter setting. Also set up output ganging.
INTERFACE
INTERFACEINTERFACE
INTERFACE Sub-menu: Comms interface setup (RS232 and RS485),
G.P.I. interface configuration, and wireless interface.
SYSTEM
SYSTEMSYSTEM
SYSTEM
Sub-menu: Used to view unit’s status, and select various
global options such as PEQ ‘Q’ or bandwidth units, delay units, and
output metering point (pre/post mute).
SECURITY
SECURITYSECURITY
SECURITY
Sub-menu: Used for locking various operations of the
unit, using a 4 digit code.
AES/EBU
AES/EBUAES/EBU
AES/EBU
Sub-menu: Switch outputs from analogue to digital and
monitor AES input status info. (AES inputs are switched via rear panel.)
DYNAMIC
DYNAMICDYNAMIC
DYNAMIC Sub-menu: Change how gain reduction meters behave.
Notes
The output meters show level, in dB from the limiter threshold, and the
input meters show level from clipping the A-D converters,
pre-gain and all EQ.
When editing DEQ or compressors, meters read downwards and show
gain reduction for each DEQ section or compressor respectively.
The high and low pass crossover filters are defined independently on
each output channel.
To access the limiter attack and release parameters, select “AutoLimiter
TimeCst: No” when designing a crossover.
To swap parametric filter units between bandwidth (‘BandW’) and ‘Q’,
enter System
SystemSystem
System Sub-menu, select ‘Filter Q / Bandwidth’, and select
required readout units.
To swap delay time units, enter System
SystemSystem
System Sub-menu, select ‘Delay
Time / Distance’, and select required readout units.
Pressing an EDIT key flashes corresponding channels routed to / from
that channel.

Table of Contents

Related product manuals