DPA Series — DPA80/DPA100 Operating Instructions Page 69
t
a
x
The peak limiter follows the RMS limiter, has only two parameters to adjust — the release
time and the threshold. Note that the threshold is set to be a minimum of 2dB above the
threshold of the program limiter — setting the threshold to “10dB above” means that no more
than 10dB of overshoot above the threshold of the program limiter will ever be allowed.
The release time can also be automatically set if the RMS limiter has automatic time
constants enabled and so are set by the high pass filter frequency for that channel.