Xtreme Power Conversion Corporaon
P91, TX91, TX91L, TXVR Service Manual
Page 27
Uninterrupble Power Supply
6k Main Power Secon
Circuit Block Checked components Component Type Failure condion
FUSE F3,F4 Fuse Open
Recer Q17, Q18, Q21 SCR A-K Short or open
PFC D33, D35 Diode Short or open
Q22, Q23 IGBT C-E short or open
INV D62, D52 Diode Short or open
Q7, Q8, Q9, Q10 IGBT C-E short or open
STS Q1, Q2, Q3, Q4 SCR A-K Short or open
SPS-Charger Secon
Circuit Block Checked components Component Type Failure condion
D2, D3, D7, D8, D11 Diode Short or open
Q1, Q2 MOSFET D-S short or open
IC1 Power IC I-O short or open
Others Q28 MOSFET D-S short or open
F1 Fuse Open
REC1 Recer Bridge Short or open
Q6, Q15, Q28 MOSFET D-S short or open
D8, D16, D13, D7, D17,
D18 ,D33
Power Diode Short or open
U1, U4 Power IC I-O short or open
U9, U10 Power Control IC Vcc short to GND
Note: If the fuse is in “open” status, don’t replace the fuse only. In most of cases, open fuse is caused by other
failed components. Therefore, before restarng the UPS, you must nd all failed components and replace them.