EasyManuals Logo

Xylem sensus AutoRead User Manual

Xylem sensus AutoRead
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
Field
Name
Protocols Imp/Exp Function Max
Width
Notes
View
Alternate
Number
CI/PR Export View Command issued to obtain the
Alternate Number that is currently
set in the MIU.
50
View
Emergency
Number
CI/PR Export View Command issued to obtain the
Emergency Number that is currently
set in the MIU.
50
View
Modes
CI/PR Export View command issued to obtain
the mode settings (time, error, tone,
ring, and tamper) that are current
set in the MIU.
16
View
Primary
Number
CI/PR Export View Command issued to obtain the
Primary Number that is currently set
in the MIU.
50
View Ring
Timer
CI/PR Export View command issued to obtain the
current Ring Timer setting of the
MIU.
3
Work Order and Flexnet Programmer Fields
Field
Name
Protocols Imp/Exp Function Max
Width
Notes
Communication
Device ID
HH/TRHH/
RR
Export ID number of the transmitter as
recorded in the work order.
40
Communication
Device
Manufactured
Date
HH/TRHH/
RR
Export Manufacture Date of transmitter as
recorded in the work order.
19
Communication
Device
Type
HH/TRHH/
RR
Export Type or model information of the
transmitter as recorded in the work
order.
1
Flexnet
Compensation
Factor
HH/TRHH/
RR
Export Number between 1 and 4
used to determine pulse count
on Temperature/Pressure
compensated indexes. Entered
during programming.
15
Flexnet
Endpoint
ID
HH/TRHH/
RR
Export The actual endpoint ID programmed
via the HHD.
15
Flexnet
Index Drive
HH/TRHH/
RR
Export Number of volume measurement
units per revolution in direct mount
or per pulse if a remote mount is
selected. May be set to 1, 2, 5, 10,
20, or 100 and is entered during
programming.
5
Flexnet
Index Scale
HH/TRHH/
RR
Export Hundreds of Cubic Feet, Thousands
of Cubic Feet, or Cubic Meters.
Expressed as CCF, MCF, or Cubic
Meters and is entered during
programming.
5
Flexnet
Latitude
HH/TRHH/
RR
Export The latitude collected via the
programming tool at the location
programming was performed.
20
Appendix B: Import and Export Field Names | 152

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem sensus AutoRead and is the answer not in the manual?

Xylem sensus AutoRead Specifications

General IconGeneral
BrandXylem
Modelsensus AutoRead
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals