EasyManuals Logo

Xylem sensus AutoRead User Manual

Xylem sensus AutoRead
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #153 background imageLoading...
Page #153 background image
Field
Name
Protocols Imp/Exp Function Max
Width
Notes
Flexnet
Longitude
HH/TRHH/
RR
Export The longitude collected via the
programming tool at the location
programming was performed.
20
Flexnet
Meter 1
History
Scale
HH/TRHH/
RR
Export Used to determine the scale and
units of the current reading and
history samples.
15
Flexnet
Meter 1 ID
HH/TRHH/
RR
Export The register ID attached to Port 1 of
the transmitter as programmed by
the HHD.
40
Flexnet
Meter
1 Initial
Reading
HH/TRHH/
RR
Export The initial reading entered for the
register attached to Port 1 of the
transmitter during programming.
15
Flexnet
Meter
1 Leak
Detection
Consecutive
Reads
HH/TRHH/
RR
Export The consecutive number of intervals
with an increase in consumption
before a leak is flagged on Port 1
of the transmitter. The interval is
defined by the sample rate. Works in
conjunction with the Leak Detection
Threshold. Expressed as 24, 36, 48,
or 72 hours.
15
Flexnet
Meter
1 Leak
Detection
Threshold
HH/TRHH/
RR
Export The number of units that need to
pass per interval to flag a leak on
Port 1 of the transmitter. Works in
conjunction with Leak Detection
Consecutive Reads. Expressed as
Disabled, 1 count, 2 counts, or 10
counts.
15
Flexnet
Meter 1
Reading
Resolution
HH/TRHH/
RR
Export The resolution programmed into the
transmitter for Port 1 expressed as a
power of 10.
10
Flexnet
Meter 1
Type
HH/TRHH/
RR
Export Remote mount, single switch;
or Direct mount, dual switch as
entered through the programmer for
Port 1 of the transmitter.
30
Flexnet
Meter 1
Units
HH/TRHH/
RR
Export The units of measurement
programmed into the transmitter for
Port 1. Expressed as Cubic Feet,
Cubic Meters, Liters, or Gallons.
16
Flexnet
Meter 2
History
Scale
HH/TRHH/
RR
Export Used to determine the scale and
units of the current reading and
history samples.
15
Flexnet
Meter 2 ID
HH/TRHH/
RR
Export The register ID attached to Port 2 of
the transmitter as programmed by
the HHD.
40
Flexnet
Meter
2 Initial
Reading
HH/TRHH/
RR
Export The initial reading entered for the
register attached to Port 2 of the
transmitter during programming.
15
Appendix B: Import and Export Field Names | 153

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem sensus AutoRead and is the answer not in the manual?

Xylem sensus AutoRead Specifications

General IconGeneral
BrandXylem
Modelsensus AutoRead
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals