Field
Name
Protocols Imp/Exp Function Max
Width
Notes
Flexnet
Longitude
HH/TRHH/
RR
Export The longitude collected via the
programming tool at the location
programming was performed.
20
Flexnet
Meter 1
History
Scale
HH/TRHH/
RR
Export Used to determine the scale and
units of the current reading and
history samples.
15
Flexnet
Meter 1 ID
HH/TRHH/
RR
Export The register ID attached to Port 1 of
the transmitter as programmed by
the HHD.
40
Flexnet
Meter
1 Initial
Reading
HH/TRHH/
RR
Export The initial reading entered for the
register attached to Port 1 of the
transmitter during programming.
15
Flexnet
Meter
1 Leak
Detection
Consecutive
Reads
HH/TRHH/
RR
Export The consecutive number of intervals
with an increase in consumption
before a leak is flagged on Port 1
of the transmitter. The interval is
defined by the sample rate. Works in
conjunction with the Leak Detection
Threshold. Expressed as 24, 36, 48,
or 72 hours.
15
Flexnet
Meter
1 Leak
Detection
Threshold
HH/TRHH/
RR
Export The number of units that need to
pass per interval to flag a leak on
Port 1 of the transmitter. Works in
conjunction with Leak Detection
Consecutive Reads. Expressed as
Disabled, 1 count, 2 counts, or 10
counts.
15
Flexnet
Meter 1
Reading
Resolution
HH/TRHH/
RR
Export The resolution programmed into the
transmitter for Port 1 expressed as a
power of 10.
10
Flexnet
Meter 1
Type
HH/TRHH/
RR
Export Remote mount, single switch;
or Direct mount, dual switch as
entered through the programmer for
Port 1 of the transmitter.
30
Flexnet
Meter 1
Units
HH/TRHH/
RR
Export The units of measurement
programmed into the transmitter for
Port 1. Expressed as Cubic Feet,
Cubic Meters, Liters, or Gallons.
16
Flexnet
Meter 2
History
Scale
HH/TRHH/
RR
Export Used to determine the scale and
units of the current reading and
history samples.
15
Flexnet
Meter 2 ID
HH/TRHH/
RR
Export The register ID attached to Port 2 of
the transmitter as programmed by
the HHD.
40
Flexnet
Meter
2 Initial
Reading
HH/TRHH/
RR
Export The initial reading entered for the
register attached to Port 2 of the
transmitter during programming.
15
Appendix B: Import and Export Field Names | 153