Field
Name
Protocols Imp/Exp Function Max
Width
Notes
Flexnet
Meter
2 Leak
Detection
Consecutive
Reads
HH/TRHH/
RR
Export The consecutive number of intervals
with an increase in consumption
before a leak is flagged on Port 2
of the transmitter. The interval is
defined by the sample rate. Works in
conjunction with the Leak Detection
Threshold. Expressed as 24, 36, 48,
or 72 hours.
15
Flexnet
Meter
2 Leak
Detection
Threshold
HH/TRHH/
RR
Export The number of units that need to
pass per interval to flag a leak on
Port 2 of the transmitter. Works in
conjunction with Leak Detection
Consecutive Reads. Expressed as
Disabled, 1 count, 2 counts, or 10
counts.
15
Flexnet
Meter 2
Reading
Resolution
HH/TRHH/
RR
Export The resolution programmed into the
transmitter for Port 2 expressed as a
power of 10.
10
Flexnet
Meter 2
Type
HH/TRHH/
RR
Export Remote mount, single switch;
or Direct mount, dual switch as
entered through the programmer for
Port 1 of the transmitter.
30
Flexnet
Meter 2
Units
HH/TRHH/
RR
Export The units of measurement
programmed into the transmitter for
Port 2. Expressed as Cubic Feet,
Cubic Meters, Liters, or Gallons.
16
Flexnet
Number of
Index Dials
HH/TRHH/
RR
Export Number of significant index
dials to be read electronically as
programmed into the transmitter.
May be 2, 3, or 4 dials.
10
Flexnet
Programming
Result
HH/TRHH/
RR
Export Result of the programming attempt
on an endpoint. Possibilities include
Successful, Unsuccessful, NAK, and
Length Error.
50
Flexnet
Programming
Unsuccessful
Reason
HH/TRHH/
RR
Export Reason for the program failure.
Possibilities include No RF
Response From Module or No
RF Response From Module2 (this
indicates that a response was
received but from the wrong meter
ID.)
35
Flexnet
Sample
Rate
HH/TRHH/
RR
Export How often the transmitter reads
the register. Expressed in hours or
minutes.
15
Flexnet
Service
Type
HH/TRHH/
RR
Export W for water, G for gas, E for electric. 1
Flexnet
Signal
Noise Ratio
HH/TRHH/
RR
Export Signal strength of the transmitter to
the tower, expressed in dB.
15
Flexnet
Transmit
Mode
HH/TRHH/
RR
Export The mode the transmitter has
defaulted to after programming:
Normal, mPass, or Boost. May also
be a combination of these preceded
by a corresponding ratio.
15
Appendix B: Import and Export Field Names | 154

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem sensus AutoRead and is the answer not in the manual?

Xylem sensus AutoRead Specifications

General IconGeneral
BrandXylem
Modelsensus AutoRead
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals