Table 4. Charge Errors (Continued)
Condition LED 1 LED 2 LED 3 LED 4 LED 5
Batt Is 100%
Discharged
Off Flashing Off Off Flashing
Batt Beyond Over
Discharged
Off Flashing Off Flashing Off
Batt Emergency Under
- Voltage
Off Flashing Off Flashing Flashing
Batt Temperature
Sensor Open
Off Flashing Flashing Flashing Flashing
Batt Temperature
Sensor Shorted
Flashing Off Off Off Off
Batt Over -
Temperature
Flashing Off Off Off Flashing
Battery Storage Error Flashing Off Off Flashing Flashing
Battery Testing Error -
Sulphate
Flashing Off Flashing Off Off
Battery Testing Error -
Discharged
Flashing Off Flashing Off Flashing
Bulk Charge Safety
Time Error
Flashing Flashing Off Off Flashing
Absorption Safety Time
Error
Flashing Flashing Off Flashing Off
Excessive Safety Time
Error
1
Off Off Off Off Flashing
Mode Selected Not
Valid - Empty
1
Off Off Off Flashing Off
Product Not
Operational
1
Off Off Off Flashing Flashing
Lockout (Inhibit) Enable
Defective
1
Off Off Flashing Off Off
Lockout (Inhibit)
Disable Defective
1
Off Off Flashing Off Off
Internal Over
Temperature
1
Flashing Off Off Off Flashing
1
LEDs will flash quickly.
2240 YRM 1890 Charging and Troubleshooting
11