12
Command Class User Code, Version 2*
* This command class requires security.
Versions 1 and 2 of this command class can address user code slots 1 through 250
via the User Code Set/Get/Report commands. Version 2 of this command class also
includes extended versions of each of these commands, used to address the
extended range of users.
Table 2 – Expected Reports for Set/Get Commands
The master code can be accessed (read/write) using slot 251 (0xFB), if using
version 1 of this command class. For version 2, the Master Code Set/Get/Report
commands must be used.
Yale locks do not support bulk commands (setting or getting multiple user codes at
once) or CRC functionality for this command class.
It should be noted that the lock’s operation mode (called “User Code Keypad Mode”
in this command class) can be modified through Version 2 of this command class,
or through parameter 8 of the Configuration command class. This is the only
parameter that can be modified through more than one command class.
The following implementation notes apply specifically to non-access user codes:
• The usage of non-access users has changed slightly with ZW3, compared to
ZW2, but is still backwards compatible. If a User Code Set is transmitted
using version 1 of the command class, then the lock will accept a value of
0x04 as the status for the non-access user.