5
Non Access
0x26
0x(0001-max
users)
A Non Access Code was entered at the lock.
Where alarm level represents user slot number
Low Battery Alarms
0xA9
0x(Current %)
Too Low to operate (Starting at 3.8V)
0xA8
0x(Current %)
Critical Battery Level (Starting at 4.0V)
0xA7
0x(Current %)
Low Battery (Starting at 4.2V)
Auto Lock Operate
Locked
0x1B
0x
0001
Auto re
-lock cycle complete, locked.
Duplicate Pin
-
code
error
0x71
0x (
0001-max
users
)
Where Alarm level represents user slot number
Alarm generated in response to add user
RF
cmd.
This alarm is not generated when attempting to
add duplicate pin at the keypad. The lock simply
denies
ŝƚĂŶĚƉůĂLJƐƚŚĞĞŶŝĞĚdƌLJŝŶŐƚŽ
duplicate the master code will result in a 0x71
0x00 alarm report.
RF Module Power
Cycled
0x82
0x
0001
Power to RFM was restored, sent by RF module.
dŚĞůŽĐŬĚŽĞƐŶƚƐĞŶĚĂŶLJĂůĂƌŵƚŽƚŚĞZ&ŵŽĚƵůĞ
when power is cycled.
Disabled user
entered at keypad
0x83
0x (0001-max
users)
A disabled user pin code was entered at the
keypad. Alarm Level represents user slot number.
Valid user but
outside of schedule
0x84
0x (
0001-max
users
)
A valid user can be both a normal user and a Non-
Access user. If a non
-
access user is out of schedule
this alarm will be sent instead of the non
-access
alarm. Alarm Level represents user slot number.
Daily Repeating
Schedule
Set
0x60
User ID
Daily Repeating Schedule(s) were Set (Erased/Set)
for User ID specified in Alarm Level. If Alarm Level
= 0xFFFF then all users were affected.
Daily Repeating
Schedule
Enabled/Disabled
0x61
User ID
Daily Repeating Schedule(s) were
enabled/disabled for User ID specified in Alarm
Level. If Alarm Level = 0xFFFF then all users were
affected.
Year Day Schedule
Set
0x62
User ID
Year Day Schedule(s) were Set (Erased/Set) for
User ID specified in Alarm Level. If Alarm Level =
0xFFFF then all users were affected.
Year Day Schedule
Enabled/Disabled
0x63
User ID
Year Day Schedule(s) were Enabled/Disabled for
User ID specified in Alarm Level. If Alarm Level =
0xFFFF then all users were affected.
All Schedule Types
Set
0x64
User ID
All Schedule Types were Set (erased/set) for User
ID specified in Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
All Schedule Types
Enabled/Disabled
0x65
User ID
All Schedule types were enabled/disabled for User
ID specified in Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
** - The Yale lock also supports a 3
rd
low battery alarm, too low to operate. This alarm is sent out as a
Battery Report (with value = 0xFF) through the Battery Command Class. This is the last low battery
alarm level before the product stops functioning.