6
Configurable Parameters
Configuration
Parameters
N
Size
Description
Silent mode on/off
1 byte
Level control for YRL226, 1 = High Volume, 2 = Low
Volume
, 3 = Silent. Default is 2 or Low Volume
Level Control for YRL216
, 1 = Enabled, 3 = Disabled.
Default is 1 or
Enabled
Auto Relock on/off
1 byte
0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Auto Relock time
1 byte
10 to 180 seconds default is 30 seconds
Wrong Code Entry Limit
1 byte
3 to 10 default is 5 times
Shut down time (after
wrong code entries)
1
byte
10 to 180 seconds
default is 60 seconds
operating mode
1 byte
00 = normal mode (this is the default mode)
01 = vacation mode, keypad lockout
One Touch Locking
1 byte
0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Lock Status LED
1 byte
0x00 = OFF, 0xFF = ON default is 0x00 or OFF.
Reset To Factory
Defaults
1 byte
01 = Lock will execute Reset To Factory.
No default value