EasyManua.ls Logo

Yale Assure Lock YRL216

Yale Assure Lock YRL216
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Associ
ation Table
Group ID
Maximum Nodes
Description
Commands
1 1 Lifeline
Command_Class_Battery, Battery_Report ;
Command_Class_Notification, Notification_Report;
Command_Class_Configuration, Configuration_Report;
Command_Class_Device_reset_locally,
Device_Reset_locally_notification
Notifications Table:
Alarm Reports
Alarm
type
Alarm Level
(2Bytes)
Description
Master Code
changed.
0x70
0x0000
Master code was changed at keypad
0xFB
Master code was changed over RF
User added
0x(0001-max
users)
User added. Alarm level = user slot number
User deleted
0x21
0x(0001-max
users)
User was deleted. Alarm level = user slot number
Tamper Alarm
0xA1
0x0001
keypad attempts exceed code entry limit
0x0002
front escutcheon removed from main
Manual Unlock
0x16
0x0001
by key cylinder or inside thumb-turn
0x0002
By Inside Button
RF Operate Unlock
0x19
0x0001
by RF module
Keypad Unlock
0x13
0x(0001-max
users)
Where Alarm level represents user slot number
Manual Lock
0x15
0x0001
by key cylinder or inside thumb-turn
0x0002
by one touch function (lock and leave)
0x0003
By inside button
RF Operate Lock
0x18
0x0001
by RF module
Keypad Lock
0x12
0x (0001 ʹ max
users)
Where Alarm level represents user slot number
Deadbolt Jammed
0x09
0x0001
0x0002
Deadbolt motor jammed Locking
Deadbolt motor jammed Unlocking
Lock Reset to
Factory defaults
0x30
0x0000
lock was reset manually to factory defaults lock
0x0001
was reset over RF with a value of 0x01;
0x0002
was reset over RF with a value of 0x02; reserved
for future use

Related product manuals