9-25
IMMOBILIZER SYSTEM
Standard key registration
Voiding the standard key code:
If a standard key has been lost, it is possible to disable its use by re-registering the remaining standard
key. Standard key registration erases the stored standard key code from the memory, thus disabling the
lost standard key. To re-register, refer to “Standard key registration”.
Standard key code voiding method
a. Main switch “ON”
b. Main switch “OFF”
c. LED on
d. LED off
e. Less than 5.0 s
f. Code re-registering key
g. First standard key
h. Second standard key
i. Registration mode
A. Registration of the second standard key is
complete.
B. Immobilizer system indicator light stops flash-
ing when the registration of the second stan-
dard key is complete.
a. Main switch “ON”
b. Main switch “OFF”
c. LED on
d. LED off
e. Less than 5.0 s
f. Code re-registering key
g. Remaining standard key
h. Registration mode
A. If the immobilizer system indicator light stops
flashing 5 seconds after the first standard key
is registered, the second standard key cannot
be registered.