EasyManua.ls Logo

YASKAWA 1000 Series

YASKAWA 1000 Series
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Input Assemblies (Drive Produces)
60 YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual
Multi-Function Input 7
Terminal S7 command by Network
0: Terminal S7 command OFF
1: Terminal S7 command ON
Multi-Function Input 8
Terminal S8 command by Network
0: Terminal S8 command OFF
1: Terminal S8 command ON
Running
Running
0: Stop
1: Forward or Reverse Running
ZSP
Zero Speed
0: Running
1: Stop or DC Injection Braking
REV Running
Reverse Running
0: Not Reverse Running
1: Reverse Running
Reset
Reset
0: No Reset
1: Reset
Speed Agree
Speed Agree
0: No Speed Agree
1: Actual speed at speed reference
READY
Drive Ready
0: Not Ready
1: Ready
ALARM
Drive Alarm
0: No Drive Alarm
1: Alarm
FAULT
Drive Fault
0: No Drive Fault
1: Fault
oPE
oPE Fault
0: No oPExx fault
1: oPExx
Uv
Undervoltage
0: No Undervoltage
1: Undervoltage
2nd Motor
Status of Second Motor
0: First Motor Select
1: Second Motor Select
NetRef (Status)
Status of reference command from Network
0: Reference command is not from network
1: Reference command is from network
NetCtrl (Status)
Status of Run command from Network
0: Run command is not from network
1: Run command is from network
Output Frequency
Actual Drive Speed
Monitors drive output frequency
Unit depends on o1-03.
Unit is not affected by Speed Scale SS.
Actual Torque
Output Torque
Shows the torque reference.
Value displays in 0.1% units.