5 Installation Procedure
YASK AWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual 21
◆ LCD Operator Option Dimensions
Figure 6
Figure 6 Dimensions
<1> Use only Yaskawa cables or cables recommended by Yaskawa. Refer to Item Names
and Part Numbers (Sold Separately) on page 11.
◆ Installing the LCD Operator Option
There are two different installation methods for the LCD Operator Option depending on the
application.
1. External/Face-mount: Mounted outside a panel.
2. Internal/Flush-mount: Mounted inside a panel.
Table 10 LCD Operator Option Installation Methods
Installation Method Description Notes
External/Face-mount
Simplified installation with the LCD Operator is
mounted on the outside of the panel with two
screws.
–
<1>
90 (3.54)
78 (3.07)
60 (2.36)
7.9
(0.31)
minimum 50 (1.97) Unit : mm (in)
12.2
(0.48)
1.6 (0.06)
Installation holes
(2-M3 screws, depth 5 (0.2))
44 (1.73)
15
(0.59)
MODEL:JVOP-180ޓޓޓ REV:A
PASSED
L/N :BY1-00004 PRG:0100
S / N : J007XE273710001
YASKAWA ELECTRIC CORPORATION