4 Start-Up Programming
122 YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide
When the lightest load direction is up, the drive stops after Light Load Direction Search and then accelerates upwards to
the Rescue Operation speed set in parameter d1-25. The output terminals set for “Light Load Direction” (H2- = 54)
and “Light Load Direction detection status”(H2- = 55) will close.
Figure 72
Figure 79 Light Load Direction Detection (Up)
When the lightest direction is down, then after Light Load Direction Detection is finished the drive immediately
accelerates to the Rescue Operation speed set in d1-25 without stopping. An output terminal set for “Light load
direction” (H2- = 54) will stay open, and an output terminal set for “Light Load Direction detection status”(H2-
 = 55) will close.
Figure 73
Figure 80 Light Load Direction Detection (Down)
H1-غغ = 55
(Rescue Operation)
Up
Off (open)
Off (open)
Up
Down
Speed agree torque calculations
Elevator moves in the
direction of the light load
Up/Down command
Up command (internal)
Down command (internal)
On (closed)
On (closed)
Light Load Direction Search status
H2- = 55
Light load direction
H2- = 54
Off (open)
Off (open)
On (closed)
On (closed)
H1-غغ = 55
(Rescue Operation)
Up
Off (open)
Off (open)
Down
Speed agree torque calculations
Elevator moves in the
direction of the light load
Up/Down command
Up command (internal)
Down command (internal)
On (closed)
On (closed)
Light Load Direction Search status
H2- = 55
Light load direction
H2- = 54
Off (open)
Off (open)
On (closed)

Related product manuals