6 Periodic Inspection & Maintenance
YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide 141
Periodic Inspection &
Maintenance
6
6 Periodic Inspection & Maintenance
Inspection
Power electronics have limited life and may exhibit changes in characteristics or performance deterioration after years of
use under normal conditions. To help avoid such problems, it is important to perform preventive maintenance and
periodic inspection on the drive.
Drives contain a variety of power electronics such as power transistors, semiconductors, capacitors, resistors, fans, and
relays. The electronics in the drive serve a critical role in maintaining proper motor control.
Follow the inspection lists provided in this chapter as a part of a regular maintenance program.
Note: The drive will require more frequent inspection if it is placed in harsh environments, such as:
High ambient temperatures
Frequent starting and stopping
Fluctuations in the AC supply or load
Excessive vibrations or shock loading
Dust, metal dust, salt, sulfuric acid, chlorine atmospheres
Poor storage conditions.
Perform the first equipment inspection one to two years after installation.
Recommended Daily Inspection
Table 37 outlines the recommended daily inspection for Yaskawa drives. Check the following items on a daily basis to
avoid premature deterioration in performance or product failure. Copy this checklist and mark the “Checked” column
after each inspection.
Table 37 General Recommended Daily Inspection Checklist
Inspection Category Inspection Points Corrective Action Checked
Motor
Inspect for abnormal oscillation or noise coming
from the motor.
Check the load coupling.
Measure motor vibration.
Tighten all loose components.
Cooling
Inspect for abnormal heat generated from the drive or
motor and visible discoloration.
Check for excessive load.
Excessive load.
Loose connections.
Dirty heatsink or motor.
Ambient temperature.
Inspect drive cooling fan and circulation fan
operation.
Check for the following:
Clogged or dirty fan.
Correct fan operation parameter setting.
Environment
Verify the drive environment complies with the
specifications listed in Installation Environment on
page 17.
Eliminate the source of contaminants or correct
poor environment.
Load
The drive output current should not be higher than
the motor or drive rating for an extended period of
time.
Check for the following:
Excessive load.
Correct motor parameter settings.
Power Supply Voltage Check main power supply and control voltages.
Correct the voltage or power supply to within
nameplate specifications.
Verify all main circuit phases.