B Parameter Table
YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide 187
Parameter Table
B
H4: Analog Outputs
2
Auxiliary Speed Reference 1
(used as a second speed reference)
E1-04 (maximum output frequency)
3
Auxiliary Speed Reference 2
(used as third speed reference)
E1-04 (maximum output frequency)
E
Motor Temperature (PTC thermistor input)
oH3 Alarm detection level: 1.18 V
oH4 Fault detection level: 2.293 V
14 Torque Compensation (load cell input)
10 V = Motor rated torque
1F Not used (Through Mode)
Sets this value when the terminal is not used or when using the terminal in the pass-through
mode.
No.(Addr.) Name Description Setting
H4-01
(41DH)
Terminal FM Monitor
Selection
Selects the data to be output through multi-function analog output terminal FM.
Set the desired monitor parameter to the digits available in U-. For
example, enter “103” for U1-03.
Default: 102
Min: 000
Max: 999
H4-02
(41EH)
Terminal FM Gain
Sets the signal level at terminal FM that is equal to 100% of the selected monitor
value.
Default: 100.0%
Min: -999.9%
Max: 999.9%
H4-03
(41FH)
Terminal FM Bias
Sets the bias value added to the terminal FM output signal.
Default: 0.0%
Min: -999.9%
Max: 999.9%
H4-04
(420H)
Terminal AM Monitor
Selection
Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in U-. For
example, enter “103” for U1-03.
Default: 103
Min: 000
Max: 999
H4-05
(421H)
Terminal AM Gain
Sets the signal level at terminal AM that is equal to 100% of the selected monitor
value.
Default: 50.0%
Min: -999.9%
Max: 999.9%
H4-06
(422H)
Terminal AM Bias
Sets the bias value added to the terminal AM output signal.
Default: 0.0%
Min: -999.9%
Max: 999.9%
H4-07
(423H)
Terminal FM Signal Level
Selection
0: 0 to 10 V
1: –10 to 10 V
Default: 0
Min: 0
Max: 1
H4-08
(424H)
Terminal AM Signal Level
Selection
0: 0 to 10 V
1: –10 to 10 V
Default: 0
Min: 0
Max: 1
H3 Multi-Function Analog Input Settings (H3-02 and H3-10)
Setting Function Description (For when output is 100%)
All Modes
common
_
All Modes
common
_
All Modes
common
_
common
_
CLV
CLV/PM
V/f OLV
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_