4 Start-Up Programming
YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide 57
Start-Up Programming
4
Figure 38
Figure 38 RUN LED and Drive Operation
Menu Structure for Digital Operator
Figure 39
Figure 39 Digital Operator Menu and Screen Structure
<1> Pressing will start the motor.
<2> Drive cannot operate the motor.
<3> Flashing characters are shown as .
<4> An "X" character is used as a placeholder for illustration purposes in this manual. The LCD Operator will
display the actual setting values.
<5> The Speed Reference appears after the initial display which shows the product name.
<6> The information that appears on the display will vary depending on the drive.
Drive output speed
during stop
Speed setting
OFF
ON
Flashing
OFF
OFF
RUN LED
RUN
0%
10%
RUN
STOP
STOP
Up/Down
common_
TM
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
-MONITR-
Speed Ref 1
U1-01= 000.00%
<3>
<4>
0.0050.00
0.00%
DRV
←→
FWD
Rdy
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Monitor Menu
Rdy
- MODE - PRG
Modified Consts
HELP
HELP
DATA
- MODE - PRG
Quick Setting
DATA
HELP
- MODE - PRG Rdy
Auto-Tuning
DATA
HELP
- MODE - PRG
DATA
Programming
AUTO
-MONITR-
U
1 -01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Monitor
FWD
Rdy
-MONITR-
U1-
01 = 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Reference
FWD
Rdy
-MONITR-
U1-
02 = 0.00%
U1-03= 0.00A
U1-04= 0
DRV
Output Speed
FWD
Rdy
-MONITR-
U
2 -01= oC
U2-02= oPr
U2-03= 0.00Hz
DRV
Fault Trace
FWD
Rdy
FWD
FWD
FWD
FWD
FWD
Modified
X Parameters
RSEQ
LREF
RSEQ
LREF
RSEQ
LREF
RSEQ
LREF
RSEQ
LREF
RSEQ
LREF
YA S K A W A
L1000E
L1000E
XXXVX.X/X.XkW
XX.XX/XX.XXA
<XXXXXXXXX>
Initial Display <5>
<6>
Programming Mode <2> Drive Mode <1>
FWD
YEA_comm
RUN
0