EN 19 YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide
5 Start Up
5Start Up
Drive Setup Procedure
The illustration below shows the basic setup procedure. The steps from switching on power are explained more detailed
on the following pages.
Note: Set parameter H5-11 to 1 when setting parameters using MEMOBUS/Modbus communications.
Mechanical Installation and Wiring
Install the mechanical equipment and the hydraulic valve as described in the manufacturers documentation. L1000H
drives are designed to work with EV4 valves made by Blain Hydraulics GmbH, Heilbronn, GERMANY.
Power On
Before turning on the power supply:
Make sure all wires are connected properly. Also make sure motor phases are connected in the right sequence.
Make sure that no screws, loose wire ends, or tools are left in the drive.
After turning the power on, the drive mode display should appear and no fault or alarm should be displayed. In case of
any error refer to Troubleshooting on page 38.
Motor Rotation Direction Setup
Depending on the elevator configuration it might be necessary to change the motor direction in order to have the pump
producing oil flow in up direction when the Run command is given to the drive. Do the following to check the motor
rotation direction and set parameter b1-14 accordingly.
START
Apply main power on to the drive.
Adhere to safety messages concerning application of power.
Perform Auto-Tuning for motor parameters.
Assign functions to the analog/digital I/O terminals using
parameters H1-, H2-, H3-, and H4-.
Set up the
Acceleration/deceleration ramp (C1-)
• Jerk settings (C2-)
Perform a test run.
Fine-tuning
• Adjust P-parameters.
FINISH
Execute Teach function.
Check the motor rotation direction.
Mechanical installation
Main and control circuit wiring
.
.

Related product manuals