EasyManua.ls Logo

YASKAWA L1000H - Page 23

YASKAWA L1000H
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Start Up
YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide EN 23
Step 1: Basic Calculations - P4-01 = 1
Perform as following to provide the basic parameters:
Enter the programming menu.
Enter the pump parameter data as received with the valve package or calculated on the web page http://www.blain.de/
calc into P1- parameters.
•Set P4-01 = 1.
If teaching finished successfully, the display will first show “END” directly followed by “0”. Parameter P4-01 will be
reset to 0 automatically.
In case that the drive shows oPE12 alarm (ALM LED flashing), check and correct the P1 settings and repeat setting
P4-01 = 1.
The following table shows the data to be input:
* Only available when A1-01 = 2:
Teaching Mode Parameter Description Range/Unit
P1-01 Hydraulic Oil ISO VG Number
0: Manual Setting,
1: ISO VG 22,
2: ISO VG 32,
3: ISO VG 46,
4: ISO VG 68
0 to 4
P1-02* Temperature at 100 cSt Manual or preselected by P1-01 0 to 100 °C
P1-03* Temperature at 25 cSt Manual or preselected by P1-01 0 to 100 °C
P1-04 Ram Diameter Elevator data 10 to 1000 mm
P1-05 Number of rams Elevator data 1 to 10
P1-06 Suspension ratio Elevator data 1 to 10
P1-07 Empty car static pressure Elevator data 1 to 100 bar
P1-08 Pay load Elevator data 1 to 50000 kg
P1-09 Dynamic pressure increase Elevator data 1 to 30 bar
P1-11 Flow at 100cSt & at max. pressure
Pump data:
refer to the parameter data supplied with the valve
package or use the following web page to calculate
the values:
http://www.blain.de/calc
2.0 to 1600.0 l/min
P1-12 Flow at 25cSt & at max. pressure 2.0 to 1600.0 l/min
P1-13 Pump Rated Speed 500 to 4000.0 l/min
P1-14 Flow at empty car pressure & at 100cSt 2.0 to 1600.0 l/min
P1-15 Flow at 1 bar pressure & at 100cSt 2.0 to 1600.0 l/min
P1-16 Nominal Speed Elevator data 0.000 to 1.200 m/s
P1-17 Intermediate Speed Elevator data 0.000 to 1.200 m/s
P1-18 Inspection Speed Elevator data 0.000 to 0.300 m/s
P1-19 Leveling Speed Elevator data 0.000 to 0.150 m/s
YES
NO
Enter P1- parameters.
oPE12
alarm shown?
Set P4-01 = 1.
START
Finish

Related product manuals