EasyManua.ls Logo

YASKAWA L1000H - Page 28

YASKAWA L1000H
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Start Up
EN 28 YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide
In case that the default ramps do not match, increase or decrease, based on these defaults.
The effective ramp time can be calculated as follows:.
Up and Down Commands and Speed Reference Selection
Up / Down Command Source Selection
The input source for the Up and Down signal can be selected in parameter b1-02.
Travel Start and Stop
Travel Start
To start the elevator in the up or down direction, the following conditions must be fulfilled:
A speed reference greater than zero must be selected.
The Safe Disable signals at terminals H1 and H2 must both be closed.
An Up or Down Signal must be set at the source specified in b1-02.
Travel Stop
The drive stops under the following conditions:
The Up or Down command is cleared.
A fault occurs. The stopping method depends on the fault occurred and certain parameter settings.
The Safe Disable inputs are opened or a Base Block signal is input. In this case the drive output shuts off.
I/O Signal Setup
Note: The default setting functions can be seen in the connection diagram on page 10.
Multi-Function Digital Inputs
Assign functions to each digital input terminal using the H1- parameters.
Multi-Function Digital Outputs
Determine the function for each digital output terminal with the H2- parameters. The setting value of these
parameters consists of three digits, where the middle and right digit determines the function, and the left digit sets the
output characteristics. The output characteristics can be either “Output as selected” (0) or “Inverse output” (1).
Multi-Function Analog Inputs
The function of each analog input can be assigned in the H3- parameters.
b1-02 Up/Down source Up/Down Command Input
1 (default) Digital inputs
Terminal S1: Run in the Up direction
Terminal S2: Run in the Down direction
2 Serial Communication Serial Communications using the RS422/485 port
3 Option Board Communications option card
Leveling
Capturing Torque
Time
C1-05
C1-05
P2-15
P2-16
P2-17
C1-06
C1-08
C1-15
C1-06
P2-16
P2-18
P2-04
P2-06
P3-04 × P2-05
- P3-07 × P2-02
P3-04 × P2-07
- P3-07 × P2-03
P2-03 > 0 (Normal)
P2-03 = 0 (Energy Saving)
Accel/Decel time = C1-0x ×
∆ƒ
E1-04

Related product manuals