an R, S, or T
phase.)
(Detected
when the
main power
supply was
turned ON.)
method for three-phase
SERVOPACK) to 1 (single-
phase power supply).
A SERVOPACK fault
occurred.
Turn the power supply OFF and then
ON again. If the alarm still occurs,
the SERVOPACK may be faulty.
Replace the SERVOPACK.
Digital
Operator
Transmission
Error 1
The contact between the
digital operator and the
SERVOPACK is faulty.
Check the connector
contact.
Insert securely the connector or
replace the cable.
Malfunction caused by noise
interference.
Keep the digital operator or the
cable away from noise sources.
Digital
Operator
Transmission
Error 2
A digital operator fault
occurred.
Disconnect the digital operator and
then re-connect it. If the alarm still
occurs, the digital operator may be
faulty. Replace the digital operator.
A SERVOPACK fault
occurred.
Turn the power supply OFF and then
ON again. If the alarm still occurs,
the SERVOPACK may be faulty.
Replace the SERVOPACK.