12.4  Crimp Terminals and Insulating Sleeves
12.4.1  Σ-7S SERVOPACKs with Three-Phase, 200-VAC or DC Power Supplies
12-21
12
SERVOPACK Peripheral Devices
12.4
Crimp Terminals and Insulating Sleeves
If you use crimp terminals for wiring, use insulating sleeves. Do not allow the crimp terminals to 
come close to adjacent terminals or the case.
To comply with UL standards, you must use UL-compliant closed-loop crimp terminals and 
insulating sleeves for the main circuit terminals. Use the tool recommended by the crimp termi-
nal manufacturer to attach the crimp terminals.
The following tables give the recommended tightening torques, closed-loop crimp terminals, 
and insulating sleeves in sets. Use the set that is suitable for your model and wire size.
12.4.1
Σ-7S SERVOPACKs with Three-Phase, 200-VAC or DC 
Power Supplies
SERVOPACK 
Model: 
SGD7S-
Main 
Circuit 
Term in al s
Screw 
Size
Tightening 
Torque
[N
m]
Crimp 
Term ina l 
Horizontal 
Width
Recom-
mended 
Wire Size
Crimp 
Ter mi na l 
Model
Crimping 
Tool
Die
Insulating 
Sleeve 
Model
(From J.S.T. Mfg. Co., Ltd.)
(Tokyo Dip 
Co., Ltd.)
R70A, 
R90A,1R6A, 
2R8A, 3R8A, 
5R5A, 7R6A, 
or 120A
Connector
−
M4
1.2 to 
1.4
10 mm 
max.
AWG14
(2.0 mm
2
)
R2-4
YHT-
2210
−−
180A or 
200A
Terminal 
block
M4
1.0 to 
1.2
7.7 mm 
max.
AWG10
(5.5 mm
2
)
5.5-S4
YHT-
2210
− TP-005
AWG14
(2.0 mm
2
)
2-M4
−
TP-003
AWG16
(1.25 
mm
2
)
−
M4
1.2 to 
1.4
10 mm 
max.
AWG14
(2.0 mm
2
)
R2-4
YHT-
2210
−−
330A
Terminal 
block
M4
1.0 to 
1.2
9.9 mm 
max.
AWG8
(8.0 mm
2
)
8-4NS YPT-60N
TD-121
TD-111
TP-008
AWG14
(2.0 mm
2
)
R2-4
YHT-
2210
−
TP-003
AWG16
(1.25 
mm
2
)
−
M4
1.2 to 
1.4
10 mm 
max.
AWG14
(2.0 mm
2
)
R2-4
YHT-
2210
−−
Continued on next page.