EasyManua.ls Logo

YASKAWA YASNAC 3000G

YASKAWA YASNAC 3000G
203 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.8
COLLATING
OF
STORED
PROGRAM
AND
OFFSET
VALUE
4.7.3
PUNCHOUT
OF
TOOL
OFFSET
VALUE*
4.8.1
COLLATING
OF
STORED
PROGRAM
+
1.
Set
the
MODE
SELECT
switch
to
EDT.
2.
Depress
the
RESET
key,
and
LABEL
SKIP
lamp
lights
up.
To
check
whether
the
memory
contents
agree
with
NC
tape
contents,
proceed
as
follows:
1.
Set
the
MODE
SELECT
switch
to
the
EDT.
3.
Depress
the
OFS
key,
and
it
lights
up.
If
the
other
FUNCTION
key
than
the
OFS
key
is
selected,
part
program
is
punched
out.
2.
Depress
the
RESET
key.
Memory
is
rewound
and
LABEL
SKIP
lamp
is
illuminated.
4.
Set
the
NUMBER
at
"61"
for
punching
opera-
.
tion.
3.
Depress
the
COM
key,
and
it
will
light
up.
4.
Set
the
NUMBER
at
"62"
which
is
the
function
number
for
collating
operation,
5.
Check
to
see
that
the
tape
puncher
is
ready
to
operate.
6.
Depress
the
START
key
with
the
OFS
key
held
in.
The
puncher
6tarts
and
automatically
stops
when
the
offset
value
has
been
punched
out.
5.
Set
the
NC
tape
to
the
tape
reader.
Be
sure
that
LABEL
SKIP
lamp
remains
on.
6.
Depress
the
START
key.
The
tape
reader
starts
reading,
and
the
mem¬
ory
contents
are
collated
with
the
tape
data.
When
it
reads
rewind
stop
code,
it
automati¬
cally
stops.
7.
To
interrupt
the
punch
operation,
depress
the
RESET
key.
To
resume
the
operation,
take
the
steps
from
l.
7.
If
disagreement
with
NC
tape
is
detected,
INPUT
ERROR
lamp
lights
up
and
tape
read¬
er
stops.
Alarm
code
"18"
is
displayed.
4.7.4
SEQUENCE
OF
TAPE
DATA
STORING
AND
PUNCHING
OPERATION*
NOTES:
Select
EDT
mode.
i
Collating
is
made
only
on
significant
informa¬
tion.
Disregarded
characters
such
as
space,
tab,
and
ALL
MARK
are
ignored
during
col¬
lating
operation.
If
the
stored
data
is
different
from
program¬
med
data
because
of
omitted
leading
zero,
IN¬
PUT
ERROR
lamp
lights
up.
Depress
RESET
key.
I
Selection
of
FUNCTION
keys.
.Any
key
other
than
OFS
key
for
NC
tape.
OFS
key
for
offset
value
stored
tape.
1
4.8.2
COLLATING
OF
STORED
OFFSET
VALUE*
Set
the
NUMBER
at:
Other
than
"6l"
and
"62"
for
storing.
"61"
for
punching.
-
"62"
for
collating.
To
check
whether
the
memory
contents
agree
with
offset
value
stored
in
tape
proceed
as
follows:
Set
the
MODE
SELECT
switch
to
the
EDT.
1
.
I
Depress
the
RESET
key,
and
LABEL
SKIP
lamp
will
go
on.
2.
Depress
the
START
key
for
punching
NC
tape.
-
Depress
the
START
and
OFS
keys
at
the
same
time
for
punching
offset
value
stored
tape.
Depress
the
OFS
key,
and
it
will
be
on.
3.
Set
the
NUMBER
at
"62"
which
is
the
func¬
tion
number
for
collating
operation.
4.
Set
the
source
tape
to
the
tape
reader.
Be
sure
that
LABEL
SKIP
lamp
remains
on.
5.
Fig.
4.7.4
114
-

Table of Contents