-35-
(6) Connection with control unit: CSU-X1CU-B1
To use CSU-X1-A2 or A3, you have to connect Bright Field control unit:
CSU-X1CU-B1 to CSU-X1.
a. Connect RS232C2 connector of CSU-X1CU-F1 to RS232C1 connector of the second
control unit: CSU-X1CU-B1 with supplied cable.
b. Insert interlock key into EXT INTERFACE1/I.LOCK
c. Connect MOTOR1 of the second control unit: CSU-X1CU-B1 with BF1 connector of
CSU-X1 using BF1 cable, and MOTOR 1 with BF2 connector using BF2 cable,
respectively.
d. In the case of CSU-X1-A3, only connect MOTOR1and BF1 connector of CSU-X1.
e. Connect power cable after confirming the power switch is OFF.
Please use power receptacle with the following specification:
3-prong plug with protective earth terminal.
Rated supply voltage: 100-240VAC,
Voltage frequency range: 90-264VAC.
Rated supply frequency: 50-60Hz.,
Supply frequency tolerance: 48-63Hz.,
Max. power consumption:200VA
WARNING
z Please confirm your power supply is suitable for the rated supply voltage of the
CSU-X1 before connection.
z Please confirm all main switches of CSU-X1 and attached instruments are OFF
before connecting power cord.
z Please only use provided power cord to avoid any risks such as fire or
electrification
z Please always use 3-prong plug with protective earth terminal to avoid risk of
electrification.