Replace the cooling water in the following steps:
1. Turn off the laser power, and stop the machine;
2. Unscrew the drain valve of the water chiller, and drain the cooling water from the water chiller;
3. If there is any precipitate, wipe with a clean towel;
4. Open the protective cover of the water chiller, and fill the new distilled water into the water chiller;
5. Start the machine, and it will work properly when the laser tube is filled with cooling water.
4.4.3 Worktable maintenance
CMA1325C-BA uses homemade hollow blade and collection box of Han's Yueming; if the exhaust port is
blocked due to too much broken materials in the collection box, the produced dust can’t be discharged promptly
and it is easy cause a fire. Please clean the blade and collection box regularly, and clean up the broken materials
promptly. Note the following aspects during use:
In daily work of the machine, pay special attention to protect the blade and avoid blade damage due to
external forces;
After processing, clean the debris adhered to blade surface with a flexible brush, and avoid scratching
the oxide layer of the blade in cleaning process;
Avoid blade contacting with corrosive liquids or gases;
If damaged or deformed, remove the damaged blade directly for replacement;
Do not place heavy object on the blade plane, or else it will cause blade bending or deformation.
Fig.5-4 Collection Box
4.5 Maintenance cycle
The maintenance period of laser, chiller and air compressor in accordance with the maintenance cycle
stated on the manual.
The machine tool requires initial inspection after 24 hours of the first use, re-inspection after 100 hours,
one inspection after six months, and then one after every six months or a year (depending on the