5.4 FUNCTION CONFIGURATION
5.4.1 "Dualac2" and "Dualac2 Power" - Master
Using the CONFIG MENU of the programming console, the user can configure the follow-
ing functions (see "OPERATIONAL FEATURE" chapter for an explanation of "hydraulic
steering function") :
SUBMENU "SET OPTIONS"
1 HOUR COUNTER
- RUNNING: the counter registers travel time only.
- KEY ON: the counter registers when the "key" switch is closed.
2 BATTERY CHECK
- ON: the battery discharge level check is carried out; when the bat-
tery level reaches 10%, an alarm is signalled and the maximum
current is reduced to the half of the programmed value.
- OFF: the battery discharge level check is carried out but no alarm is
signalled.
3 HYDRO KEY ON
- ON / OFF: if this option is programmed ON the traction inverter manages
an hydraulic steering function when the "key" is switched ON.
4 STOP ON RAMP
- ON: the stop on ramp feature (truck electrically hold on a ramp) is
managed for a time established by "auxiliary time" parameter.
- OFF: the stop on ramp feature is not performed.
5 AUX INPUT #1
- EXCLUSIVE HYDRO: input C10 activates hydraulic steering function, output
A31 is activated.
- OPTION #1: input C10 is the input for an handbrake device, active low
(open switch).
- CUTBACK SPEED: input C10 is the input for a speed reduction device, active low
(open switch).