5.6.4 "Dualac2&hp" and "Dualac2&hp Power" Tester: user can verify the state of
the following parameters:
MASTER SLAVE
motor voltage (%) motor voltage (%)
frequency (Hz) frequency (Hz)
encoder (Hz) encoder (Hz)
slip value (Hz) slip value (Hz)
current rms (A) current rms (A)
temperature (°C) temperature (°C)
temperature #1 (°C) seat switch (ON/OFF)
temperature #2 (°C) forw. switch (ON/OFF)
accelerator (V) back. switch (ON/OFF)
steer angle (°) enable switch (ON/OFF)
brake pedal poti (%) lift control (V)
int wheel cutback (%) lifting switch (ON/OFF)
seat switch (ON/OFF) 1st speed switch (ON/OFF)
forw. switch (ON/OFF) 2nd speed switch (ON/OFF)
back. switch (ON/OFF) 3rd speed switch (ON/OFF)
enable switch (ON/OFF) 4th speed switch (ON/OFF)
brake switch (ON/OFF) 5th speed switch (ON/OFF)
cutback switch (ON/OFF) pump current (A)
exclusive hydro (ON/OFF) pump vmn (V)
hand brake (ON/OFF) pump temperature (°C)
voltage booster (%) battery voltage (V)
battery voltage (V) voltage booster (%)
battery charge (%)
5.6.5 Save function (for storing data) --> only with Pc-console
5.6.6 Restore function (for downloading parameters to another controller) --> only
with Pc-console
5.6.7 Display of the last 5 alarms including hour-meter value and temperature at
the moment of the alarm.
5.6.8 Accelerator range programming
Records the minimum and maximum useful accelerator stroke values for both
direction of running.
5.6.9 See the console manual for a detailed description of function and param-
eters.