EasyManua.ls Logo

Zapi DUALAC2 - Page 67

Zapi DUALAC2
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 67
7) SEAT SWITCH: the level of the Seat Microswitch digital input.
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
8) FORWARD SWITCH: the level of the Forward direction digital input FW.
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
9) BACKWARD SWITCH: the level of the Reverse direction digital input BW.
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
10) ENABLE SWITCH: the level of the Enable digital input:
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
11) LIFT CONTROL: voltage of the lifting potentiometer (CPOT LIFT).
12) LIFTING SWITCH: status of the lifting switch.
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
13) 1 ST SPEED SWITCH: status of the first speed switch of the hydraulic system.
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
14) 2 ND SPEED SWITCH: status of the second speed switch of the hydraulic system.
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
15) 3 RD SPEED SWITCH: status of the third speed switch of the hydraulic system..
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
16) 4 TH SPEED SWITCH: status of the fourth speed switch of the hydraulic system..
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
17) 5 TH SPEED SWITCH: status of the fifth speed switch of the hydraulic system..
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
18) HYDRO SPEED REQ.: status of the hydro speed request of the hydraulic system..
ON / +VB = input active, switch closed.
OFF / GND = input non active, switch open.
19) PUMP CURRENT: current of the pump motor.
20) PUMP VMN: voltage between pump chopper output and -BATT.
21) PUMP TEMPERATURE: temperature of pump chopper power section.

Table of Contents

Related product manuals