Zaxis Isaac HD - Occlusion Testing; Occlusion Test Setup Details

Default Icon
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
53
Occlusion
The occlusion test will check for blockages in the air flow path of a part. This test is similar in
setup to a pressure decay test with two exceptions, first no settle step is used, and an occlusion
test needs to see a large drop in pressure in the test step. The clamping output can be used to
drive devices or pinch tooling to clamp off the part prior to test. During the test step these
outputs can change states to allow the part to vent opposite to their filling location.
P
R
E
S
S
U
R
E
TIME
Fill
Test
Vent
Bad Part
Min.
Pressure
Drop
Good Part