Occlusion
The occlusion test will check for blockages in the air flow path of a part. This test is similar in
setup to a pressure decay test with two exceptions, first no settle step is used, and an occlusion
test needs to see a large drop in pressure in the test step. The clamping output can be used to
drive devices or pinch tooling to clamp off the part prior to test. During the test step these
outputs can change states to allow the part to vent opposite to their filling location.