Page #204 background imageLoading...
Page #204 background image
HRM
Zilog
HRM
The
port
addresses
shown
in
Table
5-4
are
used
in
the
Moni-
tor
Program.
Table
5-4
System
Hardware
I/O
Port
Addresses
PORT
ADDRESS
CTC
CHANNEL
0
CTC
CHANNEL
1
CTC
CHANNEL
2
CTC
CHANNEL
3
SIO
DATA
CHANNEL
A
SIO
DATA
CHANNEL
B
SIO
CONTROL
CHANNEL
A
SIO
CONTROL
CHANNEL
B
RETI
PORT
SYSTEM
CONFIGURATION
PORT
(or
REGISTER)
FFA1
FFA3
FFA5
FFA7
FF81
FF83
FF85
FF87
FFE1
FFC1
- 2
bits
baud
rate,
2
bits
boot
device,
4
bits
other
configurations
5.10~
Monitor
I/O
Procedures
The
I/O
procedures
most
frequently
used
in
the
Monitor
Pro-
gram
are
given
in
this
section.
These
procedures
are ac-
cessed
by
syste~
calls
in
user
programs
to
perform
console
I/O
functions.
5.10~1.
I/O
PFocedures:
PROCEDURE
NAME
TYIN
DESCRIPTION
Gets
a
character
from
the
keyboard
buffer.
If
the
buffer
is
empty,
this
procedure
waits
for
a
character
to
appear.
The
character
is
stored
in
register
RLO,
and
the
contents
of
re-
gister
RHO
are
lost.
EXAMPLE
CONSTANT
TYIN
:=%04
5-41
Zilog
5-41

Table of Contents

Other manuals for ZiLOG System 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZiLOG System 8000 and is the answer not in the manual?

ZiLOG System 8000 Specifications

General IconGeneral
BrandZiLOG
ModelSystem 8000
CategoryDesktop
LanguageEnglish

Related product manuals