Loading...
HRM
ERROR
MESSAGES:
Zilog
HRM
SMDTEST
displays
and
logs
error
messages
with
the
for-
mat
described
in
the
INTRODUCTION
TO
SMD
DIAGNOSTICS.
The
possible
contents
of
the
Operation
Field
are:
OPERATION
FIELD
Field
Contents
WRITE
SECTOR
READ
SECTOR
WRITE
xxxx
BYTES
READ
xxxx
BYTES
Explanation
The
diagnostic
was
writing
a
single
sector
in
test
1.
The
diagnostic
was
reading
a
single
sector
in
test
1.
The
diagnostic
was
writing
a
random-length
buffer
in
t
est
2.
Th
e 1
eng
t h
in
by
t es
replaces
"xxxx"
(hexadecimal).
The
diagnostic
was
reading
a
random-length
buffer
in
t
est
2.
Th
e 1
eng
t h
in
b
yt
es
replaces
"xxxx"
(hexadecimal).
SMDTEST
will
also
display
the
following
messages:
CMP
ERR
IN BUFFERS:
SRC<ss>soff=sd
DST<ds>doff=dd
ORIG
BUFS: WR<ws>woff
RD<rd>roff
L=llll
DISK:u,cccc,hh,ss
A
mismatch
was
found
comparing
the
buffer
written
to
the
buffer
read.
The
addresses
and
data
where
the
data
mismatch
occurred
are
given
by
SRC
and
DST. The
address
and
data
in
the
write
buffer
where
the
mismatch
occurred
replace
"ssft
(segment,
decimal),
"soff"
(offset,
hex)
and
"sd"
(data,
hex).
The
address
and
data
in
the
read
buffer
where
the
mismatch
was
found
replace
"ds"
(seg-
ment,
decimal),
"doff"
(offset,
hex)
and
"dd"
(data,
hex).
Similarly,
the
beginning
addresses
of
the
write
and
read
buffers
are
given
by'
the
values
following
WR
and
RD.
The
buffer
length
in
bytes
replaces
"1111"
(hexadecimal).
A-53
Zilog