HRM
TEST
NAME
NEWMEM1
PARAMETERS
Zilog
HRM
maxseg=maximum
segment
nwnber
to
be
tested
(Jefaul
t=3)
minseg=minimum
segment
number
to
be
tested
(default=O)
DESCRIPTION
NEWlVIEM1
does
a
random
data
test
on
the
memory
segments
given
in
the
par
ameter
s . Each memor y
segmen
tis
64
K
byte.3.
Tl1
e
test
gets
repeated
n
times,
where
n=#REPS
in
the
test
line.
NEWMEM1
must
relocate
the
test
code
if
3egme~t
J
is
t23t2i.
If
minseg=maxseg=O,
the
code
is
relocated
to
segme~t
1
and
the
test
runs
from
segment
1.
If
minseg=O
and
maxseg>O,
the
code
rotates
through
the
segments
to
be
tested.
On
the
first
lap,
the
code
is
in
segment
0;
on
the
second
lap,
it
is
in
segment
1,
and
so
on.
On
each
lap
all
the
segments
from
0
to
maxseg
are
tested
except,
of
course,
the
segment
where
the
code
resides
currently.
This
implies
that
at
least
tAO
repetitions
must
be
done
for
thorough
testing.
The
test
fills
each
segment
with
random
data,
then
reads
it
back
for
verification.
ERROR
MESSAGES
If
the
data
found
in
a
memory
location
is
not
correct,
a
RANDOM
TEST
ERROR
message
appears.
It
gives
the
address
where
the
error
occurred,
what
the
data
should
be
(DATA=),
and
what
was
found
In
memory
(BAD=),.
All
NEWMEM1
errors
are
reported
as
HARD
errors.
LAP
SUMMARY
After
each
repetition
of
NEWMEM1,
the
last
19
error
messages
are
displayed.
The
errors
are
accumulated
from
one
repeti-
tion
to
the
next.
A-99
Zilog
A-99

Table of Contents