Page 14 of 32 802742UK - G4 IS IT industrial installation instructions - Jan 2016 - V2.03
Ventilation
Alternative arrangement (Dual fan kit)
In situations where the preferred arrangement cannot be used or will not work effectively e.g.
• Single cupboard where the 100mm grille spacing cannot be achieved.
• Where there are openings in the back of the cupboard allowing exhaust air to recirculate into the cupboard
space.
An SP93156 Dual exhaust fan kit* must be fitted in either arrangement A or B shown below and connected to
the DIN socket on the Command-Centre
TM
.
A Fan kit fitted to kick board and with kick space duct fitted to the Command-Centre
TM
.
B Fan kit fitted to cupboard door (position B1) or side (position B2) and without kick space duct fitted to the
Command-Centre
TM
.
*
For dual exhaust fan cut-out dimensions see the instructions provided with the kit.
BA
B2
B1
Alternative arrangement (Vent tray)
In situations where cupboard width is 1000mm or greater, without central pillar and where vent grilles cannot
be fitted in the kick board (e.g. hospitals).
Position a vent
grille in the
cupboard end or
inlet grille on the baseboard
Inlet grille
Vent tray
100mm
min.
100mm min.
Inlet grille should be
fitted on baseboard
• Use the Vent tray kit.
• The flat vent grille, supplied should be used as an
inlet vent and fitted to the cabinet side (adjacent
to the Command-Centre air inlet) or angled inlet
grille fitted in baseboard, if 100 mm separation
from Vent tray
exhaust can be
achieved.