802742UK - G4 IS IT industrial installation instructions - Jan. 2016 - V2.03 Page 29 of 32
Trouble shooting
System fault
message
Possible cause Solutions
Power Board Fault Electrical disruption Check power supply and all fuses
Interface Fault Internal fault Call Zip Service
Level Board Fault Internal fault Call Zip Service
Condenser Screen Blocked Blocked air filter Remove blockage / clean filter / check user guide
Water leak, Isolate Mains Water leak Turn off mains water supply / call for service
Compressor Over Run Compressor too hot Check ventilation
Water Supply Failure No water Check water supply is turned ON
Hot Sensor Open Internal fault Call Zip Service
Hot Sensor Closed Internal fault Call Zip Service
Cold Sensor Open Internal fault Call Zip Service
Cold Sensor Closed Internal fault Call Zip Service
Flood Sensor Open Internal fault Call Zip Service
Condenser Sensor Closed Internal fault Check ventilation / call Zip Service
Condenser Sensor Open Internal fault Check ventilation / call Zip service
Heater Fuse / Driver Fault Internal fault Call Zip Service
Heater Driver Fault No hot water Call Zip Service
Compressor Driver Fault No chilled water Call Zip Service
Hot Sensor Degraded Internal fault Call Zip Service
Condenser Overtemp Blocked air filter Remove blockage / clean filter / check user guide
Cold Overload Internal fault Call Zip Service
Steam too Cool Internal fault Call Zip Service
Steam Sensor Open Internal fault Call Zip Service
Steam Sensor Closed Internal fault Call Zip Service
Hot overload Internal fault Turn OFF to reset / Call Zip Service
Hot Tank Over filled Internal fault Call Zip Service
Outputs fuse fault Internal fault Call Zip Service
Overload Reset Internal fault Call Zip Service
Call an electrician, a plumber, or Zip on 0845 6 005 005 or 0345 6 005 005 for assistance, service, spare parts
or enquiries.